Magnetism
(A detailed introduction to magnetism can be found at:
11-14 Magnetism).
Magnetic
properties of materials
The science of magnetism has come a long way since 600
B.C. when the Greeks discovered that the iron ore lodestone (first found in Magnesia in Asia
Minor and now known as magnetite) had some interesting properties. A piece of lodestone
suspended by a thread, would always point in the same direction. The word lodestone comes
from the Saxon loedan (to lead).
Permanent magnetic materials are now used in
many applications from magnetic ink on cheques to magnetic door catches.
Magnetic materials possess a property known as susceptibility (
c) defined as follows:
B =
mo(H + M) =
moH(1 + M/H) =
moH(1 +
c) where the quantity M/H (=
c) is the
susceptibility.
Magnetic materials are of three types: (a) diamagnetic, (b)
paramagnetic and (c) ferromagnetic.
(a) DiamagneticsIf a
sample of diamagnetic material is placed in a magnetising coil and a current passed through
the coil, then a field is produced in the specimen that opposes the direction of the original
magnetising field. The susceptibility is therefore negative (-1.7 x 10
-8 for bismuth, for
example).
The electron magnetic moments will cancel out in a diamagnetic material,
because of their orbital motion and spin. The value of the relative permeability for diamag-
netics is slightly less than 1, usually about 0.9999.
(b)
ParamagneticsAn application of an external field produces a field within the specimen in
the same direction as the initial magnetising field. The susceptibility is therefore positive
(+0.82x10
-8 for aluminium).
In the paramagnetic material the electron magnetic
moments tend to add up; thermal motion disturbs them but if an external field is applied they
realign. Paramagnetism is temperature-dependent, since at low temperatures there is little
thermal motion and so the susceptibility is higher.
The value of the relative
permeability of paramagnetic materials is slightly greater than 1, usually about
1.001.
(c) FerromagneticsIn ferromagnetic materials there is
a strong linkage between neighbouring atoms to form what are known as magnetic domains.
The relative permeability of ferromagnetics is large, of the order of 10
4, but does depend on
the past history of the specimen. The only ferromagnetic elements are iron, nickel, cobalt,
gadolinium and dysprosium, but there are many ferromagnetic alloys. Modern quantum
physics actually predicts that ferromagnetism will only occur for the elements listed
above.
A simplified diagram of magnetic domains is shown in Figure 1. It is not
meant to show any particular domain shape or size.
However the length of a magnetic
domain in a ferromagnetic material is of the order of 20
m (2x10
-2 mm).
In diagram
(a) an unmagnetised specimen is shown and diagram (b) shows the effect of magnetizing the
specimen. The direction of the magnetic axis in each domain is changed to become more
aligned with the external field and some of the boundaries of the domains have changed.
When all the domains
have been aligned the material is said to be saturated and any further increase in he
external field will not produce an increase in the magnetisation of the specimen. Generally
big samples give big magnetic fields.
The Barkhausen effect
The
existence of domains in a ferromagnetic material may be shown by the Barkhausen . effect,
using the apparatus shown in Figure 2. If the north pole of the magnet is moved slowly
across the top of the bundle of iron wires a rushing sound is heard from the loudspeaker.
This is due to currents induced in the coil as the molecular domains align themselves during
magnetisation. No subsequent noise is produced if the north pole is moved across again, the
effect returning only if a south pole is used.
The Curie temperature
When
a ferromagnetic material is heated the domain boundaries are destroyed, and above a
certain temperature known as the Curie point (about 1043 K for iron, 1384 K for cobalt, and
631 K for nickel) ferromagnetics become paramagnetics.
Hysteresis
Hysteresis (the name comes from the Greek word meaning 'delay') describes the
relation between the magnetising field and the magnetisation produced within a
specimen.
Figure 2 shows the relation
between the magnetising force and the resultant magnetisation of the specimen. You will see
that there is a maximum flux that can be produced within a given specimen, shown as Bm on
the graph. This is known as saturation. In other words you need a physically large permanent
magnet to produce a large magnetic field.
If a specimen is fully magnetised and then
demagnetised, it will not return to a condition where both the magnetising field and the
magnetisation produced in the specimen are both zero.
When the magnetising field
is reduced to zero there will still be a small amount of magnetisation left in the specimen.
This is known as the remanent flux and the effect as remanence (Br). This is shown by the
length OA in Figure 2.
The area enclosed by the hysteresis loop represents the work
done in taking the material through the hysteresis cycle. This is typically about 2x10-2 J for a
soft magnetic material such as iron.
The reverse field needed to reduce the
magnetisation in the specimen to zero is known as the coercivity (H) of the specimen and is
shown as OD in Figure 2.
The loop
produced when the magnetising field is taken through a full cycle is called a hysteresis loop.
One very important factor is the area within the loop, since this represents the loss of energy
within the specimen when it is magnetised and demagnetised. This energy is lost as heat
within the specimen, and the larger the area within the loop the more energy is lost in
magnetising and demagnetising the specimen.
A soft magnetic material (soft iron)
will have a small energy loss and therefore a narrow hysteresis loop while that for a hard
magnetic material (steel) will be wider. Figure 3 shows the effect of hysteresis in two different
types of specimen. This also shows that it is hard to magnetise and demagnetise steel while
it is relatively easy to do this for iron.
(Compare the hysteresis loop formed by
magnetizing and demagnetizing a specimen with that formed by taking a rubber cord through
a cycle of stretching and relaxing).
We
can demagnetize a magnetised piece of iron by putting it in a coil of wire through which an
alternating current is passing. This will magnetise it in alternate directions but if we now
slowly reduce the current (as therefore the magnetising field) to zero the amount of
magnetisation will become less and less and finally the bar will be effectively demeagnetised.
This is shown in Figure 4.
The table below gives the remanence and coercivity
for a number of magnetic materials.
Permanent magnets are made with hard magnetic
materials with a high remanence, so that the magnet will retain its magnetism after
magnetisation, and a high coercivity so that stray fields will not affect it.
Soft
magnetic materials are used in transformer cores so that the energy losses are small. For
example, at a frequency of 50 Hz the power loss per kilogram of mumetal is 0.2 W for a
saturation field of 0.1 T. This rises to 175 W for a frequency of 2.4 kHz
WORD VERSION AVAILABLE ON THE SCHOOLPHYSICS CD